The conventional treatment for an amputation above the knee is a specially fitted cup-like shell called a socket. It fits over the remaining portion of the patients’ leg and helps secure the device to the leg. If patients do not have a long enough residual limb to properly fit socket prosthesis or have other conditions, such as scarring, pain, recurrent skin infections, or fluctuations in the shape of the residual limb they are just out of luck.
To remedy that situation the FDA has authorized the first prosthesis to be marketed in the U.S. for patients who cannot use the conventional socket prosthesis. The device is called the Osseoanchored Prostheses for the Rehabilitation of Amputees (OPRA). It uses fixtures and screws that are implanted into the patient’s remaining thigh bone to connect an external limb.
According to the FDA press release, the OPRA device is installed with two surgical procedures. In the first procedure, a cylinder-shaped fixture is implanted into the central canal of the remaining thigh bone. Approximately six months later, after tissue has grown to anchor the fixture and the skin tissue has healed, a second surgery is performed to implant a rod that attaches to the fixture from the previous surgery. This rod extends through the skin at the bottom of the patient’s residual limb and connects to the prosthetic leg.
After the second surgery, the patient works with a specially trained physical therapist to gradually place weight on the OPRA device using a training prosthesis. Patients require about six months of training and rehabilitation after the second surgery, before being fitted with their own customized prosthesis.
“Prostheses can help people who have lost a leg due to trauma or cancer to regain mobility and to more easily participate in everyday activities, ” said William Maisel, M.D., M.P.H., acting director of the Office of Device Evaluation in the FDA’s Center for Devices and Radiological Health. “The OPRA device may help those with above-the-knee amputations who have had problems with rehabilitation and have not been able to benefit from available socket prostheses.”
The OPRA device is manufactured by Integrum AB in Molndal, Sweden.


There is a serious health issue with this procedure. That rod, protruding through the skin, prevents the skin from sealing 100% perfectly, allowing a route for infection to penetrate the body.
Considering many amputees are diabetics with a compromised health system anyway, this has the risk of being very dangerous. I had the opportunity to see a patient once with a procedure like this. When we looked at it, we noted that pus was oozing from the area the rod protruded from his body.
When we pointed this out, he shrugged and said it was no big deal, it happened all the time.
If they have a way to perfectly seal the skin or otherwise prevent infectious agents from reaching the inner workings of the body, that’s great, but otherwise, this is a serious risk for amputees to take.
I am a left leg aka since 1998. I have had numerous prosthetic legs which none have really worked for me. I have tried different socket designs and my back and ankle have suffered along with my wrists due to having to use crutches. I would love to visit with someone to see if I would be a good canidate for this procedure. I am a young 58 year old male and plum tired of needing a wheelchair just because sockets have not worked for me. Will be waiting on your response. Thank you.
Californian/Okie
Ron Galloway